Mavis-ics-arm Manual Jun 2026
: Rated IP66 for dust and water protection, featuring a powder-coated mild steel case with a viewing window for direct circuit board monitoring.
Verify the tachometer speed-sensor wheel makes firm, non-slip contact with the underside of the conveyor belt. Error Code Diagnostics Error Code / Symptom Root Cause Corrective Action "Density Drift Error" Misalignment between optical scanner data and scale data.
Perform zero and span calibration to ensure accuracy. The system requires stable tension to maintain high calibration accuracy over long periods.
The system gathers real-time cross-sectional metrics. Adjust the calibration scale factoring until the calculated bulk density matches the physical laboratory sample density: mavis-ics-arm manual
: Includes TCP/IP network access for remote monitoring and data management. Control Systems Technology Operational & Maintenance Features
The is an Intelligent Cargo Scale (ICS) developed by Control Systems Technology (CST) . It is a multifunctional weighing electronic system designed primarily for bulk material handling, such as ship loading and belt weighing. Standard Hardware Features
Designed for industrial applications, typically operating on : Rated IP66 for dust and water protection,
. Primarily used in heavy industries like mining and port loading, it acts as a central hub for trade-certified belt weighers and volumetric scanners.
Inspect the Volumetric Laser lens for dust accumulation. Clean using low-pressure compressed air or optical wipes.
: Designed for direct force measurement (eliminating lever arms or pivots) with accuracy up to 1.0% . Perform zero and span calibration to ensure accuracy
The MaVIS-ICS-ARM is robust, but when problems arise, know how to respond:
Connect an integrated laser scanner directly to the control unit. While the load cells capture mass, the scanner registers cross-sectional area, material center-of-load, belt tracking lines, and material surcharge angles. Combining these readings provides three real-time density metrics on the display:
For the most critical tasks, always refer to the official documentation from . Here’s how to get it:
Even experienced integrators make these three errors routinely: